Areas of Usage: These cables are designed to provide communication between devices can be used in many areas from control engineering to security systems.
PRODUCT CODE:FCLC3100
CORE NUMBERS x SECTION:3x1,00mm²
STRANDED COPPER CONDUCTER
(Cu):32x0,188 mm
INSULATION MATERIAL AND DIAMETER(mm ±0,05) :PVC 2,5
OUTER SHEATH AND DIAMETER
(±0,10):PVC 6,70
SHIELDING:85% COVERAGE SnCu BRAIDING
WEIGHT (WITHOUT REEL):76
CONDUCTOR RESISTANCE:< 20Ω/km.
INSULATION RESISTANCE:< 200MΩ x km.
OPERATING VOLTAGE:300/500V
CAPACITANCE (pF/m):130 pF/m
WORKING TEMPERATURE:-30-70°C
BENDING RADIUS:8x outer diameter
Areas of Usage: These multiple wire bare copper or tinned copper cables, produced with flame retardant durable PVC are used in the installation of motor vehicles.
PRODUCT CODE:FB600
CROSS SECTION (Cu):6,00 mm²
STRANDED COPPER CONDUCTER
(Cu):84x0,29 mm
INSULATION MATERIAL AND DIAMETER(mm ±0,05) :PVC (according to ISO 6722-1, CLASS B AND CLASS C) 4,15
MIN. WALL THICKNESS
(mm):0,32
APPROXIMATE WEIGHT
(kg/km):61,00
CONDUCTOR RESISTANCE:<3,14 Ω/km
WORKING TEMPERATURE:-40 to +105°C (CLASS B)
These multi-strand bare copper or tinned copper multi-core cables, produced in accordance with ISO 6722-1 CLASS B and CLASS C, are used in the installation of motor vehicles.
PRODUCT CODE:FRY10035
CORE NUMBERS x CROSS SECTION (mm²):10x0,35
STRANDED COPPER CONDUCTER
(N/mm):12x0,21
INSULATION MATERIAL AND DIAMETER(mm ±0,05):PVC (according to ISO 6722-1, CLASS B and CLASS C) 1,4
INSULATION THICKNESS
(mm):0,25
SHEATH THICKNESS
(mm):0,50
OVERALL DIAMETER:6,30
CONDUCTOR RESISTANCE:<54,4 Ω/km
WORKING TEMPERATURE:-40 to +105°C (CLASS B)
Areas of Usage: These multi-strand bare copper or tinned copper multi-core cables, produced in accordance with ISO 6722-1 CLASS B and CLASS C, are used in the installation of motor vehicles.
PRODUCT CODE:FRY1025
CORE NUMBERS x CROSS SECTION (mm²):10x2,5
STRANDED COPPER CONDUCTER
(N/mm):50X0,26
INSULATION MATERIAL AND DIAMETER(mm ±0,05):PVC (according to ISO 6722-1, CLASS B) 3,0
INSULATION THICKNESS
(mm):0,30
SHEATH THICKNESS
(mm):0,80
OVERALL DIAMETER:13,70
CONDUCTOR RESISTANCE:<7,6 Ω/km
WORKING TEMPERATURE:-40 to +105°C
Areas of Usage: These multi-strand bare copper or tinned copper multi-core cables, produced in accordance with ISO 6722-1 CLASS B and CLASS C, are used in the installation of motor vehicles.
PRODUCT CODE:FRY7100
CORE NUMBERS x CROSS SECTION (mm²):7x,1,00
STRANDED COPPER CONDUCTER
(N/mm):32x0,21
INSULATION MATERIAL AND DIAMETER(mm ±0,05) :PVC (according to ISO 6722-1, CLASS B) 2,1
INSULATION THICKNESS
(mm):0,30
SHEATH THICKNESS
(mm):0,60
OVERALL DIAMETER:6,10
CONDUCTOR RESISTANCE:<18,5 Ω/km
WORKING TEMPERATURE:-40 to +105°C
Areas of Usage: These multi-strand bare copper or tinned copper multi-core cables, produced in accordance with ISO 6722-1 CLASS B and CLASS C, are used in the installation of motor vehicles.
PRODUCT CODE:FRY2075
CORE NUMBERS x CROSS SECTION (mm²):2x0,75
STRANDED COPPER CONDUCTER
(N/mm):24x0,21
INSULATION MATERIAL AND DIAMETER(mm ±0,05) :PVC (according to ISO 6722-1, CLASS B) 1,9
INSULATION THICKNESS
(mm):0,30
SHEATH THICKNESS
(mm):0,60
OVERALL DIAMETER:3,70
CONDUCTOR RESISTANCE:<24,7Ω/km
WORKING TEMPERATURE:-40 to +105°C
These multi-strand bare copper or tinned copper multi-core cables, produced in accordance with ISO 6722-1 CLASS B and CLASS C, are used in the installation of motor vehicles.
PRODUCT CODE:FRY5035
CORE NUMBERS x CROSS SECTION (mm²):5x0,35
STRANDED COPPER CONDUCTER
(N/mm):12x0,21
INSULATION MATERIAL AND DIAMETER(mm ±0,05):PVC (according to ISO 6722-1, CLASS B and CLASS C) 1,4
INSULATION THICKNESS
(mm):0,25
SHEATH THICKNESS
(mm):0,50
OVERALL DIAMETER:4,60
CONDUCTOR RESISTANCE:<54,4 Ω/km
WORKING TEMPERATURE:-40 to +105°C (CLASS B)
Areas of Usage: These cables are designed to provide communication between devices can be used in many areas from control engineering to security systems.
PRODUCT CODE:FCLC875
CORE NUMBERS x SECTION:8x0,75mm²
STRANDED COPPER CONDUCTER (Cu):24x0,188 mm
INSULATION MATERIAL AND DIAMETER(mm ±0,05):PVC 2,2
OUTER SHEATH AND DIAMETER (±0,10):PVC 8,60
SHIELDING:85% COVERAGE SnCu BRAIDING
WEIGHT (WITHOUT REEL):130
CONDUCTOR RESISTANCE:< 26Ω/km.
INSULATION RESISTANCE:< 200MΩ x km.
OPERATING VOLTAGE:300/500V
CAPACITANCE (pF/m):120 pF/m
WORKING TEMPERATURE:-30-70°C
BENDING RADIUS:8x outer diameter
Areas of Usage: These multi-strand bare copper or tinned copper multi-core cables, produced in accordance with ISO 6722-1 CLASS B and CLASS C, are used in the installation of motor vehicles.
PRODUCT CODE:FRY1075
CORE NUMBERS x CROSS SECTION (mm²):10x0,75
STRANDED COPPER CONDUCTER
(N/mm):24x0,21
INSULATION MATERIAL AND DIAMETER(mm ±0,05) :PVC (according to ISO 6722-1, CLASS B) 1,9
INSULATION THICKNESS
(mm):0,30
SHEATH THICKNESS
(mm):0,80
OVERALL DIAMETER:6,30
CONDUCTOR RESISTANCE:<24,7Ω/km
WORKING TEMPERATURE:-40 to +105°C
Areas of Usage: These multiple wire bare copper or tinned copper cables, produced with flame retardant durable PVC are used in the installation of motor vehicles.
PRODUCT CODE:FB400
CROSS SECTION (Cu):4,00 mm²
STRANDED COPPER CONDUCTER
(Cu):56x0,29 mm
INSULATION MATERIAL AND DIAMETER(mm ±0,05) :PVC (according to ISO 6722-1, CLASS B AND CLASS C) 3,55
MIN. WALL THICKNESS
(mm):0,32
APPROXIMATE WEIGHT
(kg/km):42,00
CONDUCTOR RESISTANCE:<4,71 Ω/km
WORKING TEMPERATURE:-40 to +105°C (CLASS B)
Areas of Usage: These cables are designed to provide communication between devices can be used in many areas from control engineering to security systems.
PRODUCT CODE:FCLC675
CORE NUMBERS x SECTION:6x0,75mm²
STRANDED COPPER CONDUCTER (Cu):24x0,188 mm
INSULATION MATERIAL AND DIAMETER(mm ±0,05):PVC 2,2
OUTER SHEATH AND DIAMETER (±0,10):PVC 8,10
SHIELDING:85% COVERAGE SnCu BRAIDING
WEIGHT (WITHOUT REEL):112
CONDUCTOR RESISTANCE:< 26Ω/km.
INSULATION RESISTANCE:< 200MΩ x km.
OPERATING VOLTAGE:300/500V
CAPACITANCE (pF/m):120 pF/m
WORKING TEMPERATURE:-30-70°C
BENDING RADIUS:8x outer diameter
These multi-strand bare copper or tinned copper multi-core cables, produced in accordance with ISO 6722-1 CLASS B and CLASS C, are used in the installation of motor vehicles.
PRODUCT CODE:FRY5050
CORE NUMBERS x CROSS SECTION (mm²):5x0,50
STRANDED COPPER CONDUCTER
(N/mm):16x0,21
INSULATION MATERIAL AND DIAMETER(mm ±0,05):PVC (according to ISO 6722-1, CLASS B and CLASS C) 1,6
INSULATION THICKNESS
(mm):0,28
SHEATH THICKNESS
(mm):0,60
OVERALL DIAMETER:5,60
CONDUCTOR RESISTANCE:<37,2 Ω/km
WORKING TEMPERATURE:-40 to +105°C (CLASS B)
These multiple wire bare copper or tinned copper cables, produced with flame retardant durable PVC are used in the installation of motor vehicles.
PRODUCT CODE:FLY150
CROSS SECTION (Cu):1,50 mm²
STRANDED COPPER CONDUCTER
(Cu):30x0,24 mm
INSULATION MATERIAL AND DIAMETER(mm ±0,05):PVC (according to ISO 6722-1, CLASS B AND CLASS C) 2,85
WALL THICKNESS min
(mm):0,60
APPROXIMATE WEIGHT
(kg/km):20,00
CONDUCTOR RESISTANCE:<12,7Ω/km
WORKING TEMPERATURE:-40 to +105°C (CLASS B)
These multi-strand bare copper or tinned copper multi-core cables, produced in accordance with ISO 6722-1 CLASS B and CLASS C, are used in the installation of motor vehicles.
PRODUCT CODE:FRY2035
CORE NUMBERS x CROSS SECTION (mm²):2x0,35
STRANDED COPPER CONDUCTER
(N/mm):12x0,21
INSULATION MATERIAL AND DIAMETER(mm ±0,05):PVC (according to ISO 6722-1, CLASS B and CLASS C) 1,4
INSULATION THICKNESS
(mm):0,25
SHEATH THICKNESS
(mm):0,50
OVERALL DIAMETER:3,70
CONDUCTOR RESISTANCE:<54,4 Ω/km
WORKING TEMPERATURE:-40 to +105°C (CLASS B)
These multi-strand bare copper or tinned copper multi-core cables, produced in accordance with ISO 6722-1 CLASS B and CLASS C, are used in the installation of motor vehicles.
PRODUCT CODE:FRY1050
CORE NUMBERS x CROSS SECTION (mm²):1x0,50
STRANDED COPPER CONDUCTER
(N/mm):16x0,21
INSULATION MATERIAL AND DIAMETER(mm ±0,05):PVC (according to ISO 6722-1, CLASS B and CLASS C) 1,6
INSULATION THICKNESS
(mm):0,28
SHEATH THICKNESS
(mm):0,50
OVERALL DIAMETER:2,50
CONDUCTOR RESISTANCE:<37,2 Ω/km
WORKING TEMPERATURE:-40 to +105°C (CLASS B)
Areas of Usage: These multiple wire bare copper or tinned copper cables, produced with flame retardant durable PVC are used in the installation of motor vehicles.
PRODUCT CODE:FA250
CROSS SECTION (Cu):2,50 mm²
STRANDED COPPER CONDUCTER (Cu):19x0,41, mm
INSULATION MATERIAL AND DIAMETER(mm ±0,03):PVC (according to ISO 6722-1, CLASS B and CLASS C) 3,0
WALL THICKNESS min (mm):0,28
APPROXIMATE WEIGHT (kg/km):26,00
CONDUCTOR RESISTANCE:<7,6 Ω/km
WORKING TEMPERATURE:-40 to +105°C (CLASS B)
Areas of Usage: These multiple wire bare copper or tinned copper cables, produced with flame retardant durable PVC are used in the installation of motor vehicles.
PRODUCT CODE:FB3500
CROSS SECTION (Cu):35,00 mm²
STRANDED COPPER CONDUCTER
(Cu):276x0,39mm
INSULATION MATERIAL AND DIAMETER(mm ±0,05) :PVC (according to ISO 6722-1, CLASS B AND CLASS C) 9,90
MIN. WALL THICKNESS
(mm):0,56
APPROXIMATE WEIGHT
(kg/km):371,00
CONDUCTOR RESISTANCE:<0,527 Ω/km
WORKING TEMPERATURE:-40 to +105°C (CLASS B)
Areas of Usage: These cables are designed to provide communication between devices can be used in many areas from control engineering to security systems.
PRODUCT CODE:FCLC475
CORE NUMBERS x SECTION:4x0,75mm²
STRANDED COPPER CONDUCTER (Cu):24x0,188 mm
INSULATION MATERIAL AND DIAMETER(mm ±0,05):PVC 2,2
OUTER SHEATH AND DIAMETER (±0,10):PVC 6,90
SHIELDING:85% COVERAGE SnCu BRAIDING
WEIGHT (WITHOUT REEL):79
CONDUCTOR RESISTANCE:< 26Ω/km.
INSULATION RESISTANCE:< 200MΩ x km.
OPERATING VOLTAGE:300/500V
CAPACITANCE (pF/m):120 pF/m
WORKING TEMPERATURE:-30-70°C
BENDING RADIUS:8x outer diameter
Areas of Usage: These multiple wire bare copper or tinned copper cables, produced with flame retardant durable PVC are used in the installation of motor vehicles.
PRODUCT CODE:FB150
CROSS SECTION (Cu):1,50 mm²
STRANDED COPPER CONDUCTER
(Cu):30x0,24 mm
INSULATION MATERIAL AND DIAMETER(mm ±0,05) :PVC (according to ISO 6722-1, CLASS B AND CLASS C) 2,30
MIN. WALL THICKNESS
(mm):0,24
APPROXIMATE WEIGHT
(kg/km):16,00
CONDUCTOR RESISTANCE:<12,7 Ω/km
WORKING TEMPERATURE:-40 to +105°C (CLASS B)
These multiple wire bare copper or tinned copper cables, produced with flame retardant durable PVC are used in the installation of motor vehicles.
PRODUCT CODE:FLY2500
CROSS SECTION (Cu):25,00 mm²
STRANDED COPPER CONDUCTER
(Cu):196x0,39mm
INSULATION MATERIAL AND DIAMETER(mm ±0,05):PVC (according to ISO 6722-1, CLASS B AND CLASS C) 10,1
WALL THICKNESS min
(mm):1,3
APPROXIMATE WEIGHT
(kg/km):288
CONDUCTOR RESISTANCE:<0,743 Ω/km
WORKING TEMPERATURE:-40 to +105°C (CLASS B)
These multiple wire bare copper or tinned copper cables, produced with flame retardant durable PVC are used in the installation of motor vehicles.
PRODUCT CODE:FLY3500
CROSS SECTION (Cu):35,00 mm²
STRANDED COPPER CONDUCTER
(Cu):276x0,39mm
INSULATION MATERIAL AND DIAMETER(mm ±0,05):PVC (according to ISO 6722-1, CLASS B AND CLASS C) 11,3
WALL THICKNESS min
(mm):1,3
APPROXIMATE WEIGHT
(kg/km):361
CONDUCTOR RESISTANCE:<0,527 Ω/km
WORKING TEMPERATURE:-40 to +105°C (CLASS B)
Areas of Usage: These multi-strand bare copper or tinned copper multi-core cables, produced in accordance with ISO 6722-1 CLASS B and CLASS C, are used in the installation of motor vehicles.
PRODUCT CODE:FRY415
CORE NUMBERS x CROSS SECTION (mm²):4x1,5
STRANDED COPPER CONDUCTER
(N/mm):30X0,26
INSULATION MATERIAL AND DIAMETER(mm ±0,05):PVC (according to ISO 6722-1, CLASS B) 2,4
INSULATION THICKNESS
(mm):0,30
SHEATH THICKNESS
(mm):0,60
OVERALL DIAMETER:7,10
CONDUCTOR RESISTANCE:<12,7Ω/km
WORKING TEMPERATURE:-40 to +105°C
Areas of Usage: These multi-strand bare copper or tinned copper multi-core cables, produced in accordance with ISO 6722-1 CLASS B and CLASS C, are used in the installation of motor vehicles.
PRODUCT CODE:FRY1010
CORE NUMBERS x CROSS SECTION (mm²):10x1,00
STRANDED COPPER CONDUCTER
(N/mm):32x0,21
INSULATION MATERIAL AND DIAMETER(mm ±0,05) :PVC (according to ISO 6722-1, CLASS B) 2,1
INSULATION THICKNESS
(mm):0,30
SHEATH THICKNESS
(mm):0,80
OVERALL DIAMETER:7,70
CONDUCTOR RESISTANCE:<18,5 Ω/km
WORKING TEMPERATURE:-40 to +105°C
These multiple wire bare copper or tinned copper cables, produced with flame retardant durable PVC are used in the installation of motor vehicles.
PRODUCT CODE:FLY5000
CROSS SECTION (Cu):50,00 mm²
STRANDED COPPER CONDUCTER
(Cu):396x0,39mm
INSULATION MATERIAL AND DIAMETER(mm ±0,05):PVC (according to ISO 6722-1, CLASS B AND CLASS C) 13,3
WALL THICKNESS min
(mm):1,5
APPROXIMATE WEIGHT
(kg/km):521
CONDUCTOR RESISTANCE:<0,368 Ω/km
WORKING TEMPERATURE:-40 to +105°C (CLASS B)
Areas of Usage: These multi-strand bare copper or tinned copper multi-core cables, produced in accordance with ISO 6722-1 CLASS B and CLASS C, are used in the installation of motor vehicles.
PRODUCT CODE:FRY225
CORE NUMBERS x CROSS SECTION (mm²):2x2,5
STRANDED COPPER CONDUCTER
(N/mm):50X0,26
INSULATION MATERIAL AND DIAMETER(mm ±0,05):PVC (according to ISO 6722-1, CLASS B) 3,0
INSULATION THICKNESS
(mm):0,30
SHEATH THICKNESS
(mm):0,60
OVERALL DIAMETER:7,20
CONDUCTOR RESISTANCE:<7,6 Ω/km
WORKING TEMPERATURE:-40 to +105°C
These multi-strand bare copper or tinned copper multi-core cables, produced in accordance with ISO 6722-1 CLASS B and CLASS C, are used in the installation of motor vehicles.
PRODUCT CODE:FRY3035
CORE NUMBERS x CROSS SECTION (mm²):3x0,35
STRANDED COPPER CONDUCTER
(N/mm):12x0,21
INSULATION MATERIAL AND DIAMETER(mm ±0,05):PVC (according to ISO 6722-1, CLASS B and CLASS C) 1,4
INSULATION THICKNESS
(mm):0,25
SHEATH THICKNESS
(mm):0,50
OVERALL DIAMETER:3,90
CONDUCTOR RESISTANCE:<54,4 Ω/km
WORKING TEMPERATURE:-40 to +105°C (CLASS B)
Areas of Usage: These cables are designed to provide communication between devices can be used in many areas from control engineering to security systems.
PRODUCT CODE:FCLC575
CORE NUMBERS x SECTION:5x0,75mm²
STRANDED COPPER CONDUCTER (Cu):24x0,188 mm
INSULATION MATERIAL AND DIAMETER(mm ±0,05):PVC 2,2
OUTER SHEATH AND DIAMETER (±0,10):PVC 7,50
SHIELDING:85% COVERAGE SnCu BRAIDING
WEIGHT (WITHOUT REEL):96
CONDUCTOR RESISTANCE:< 26Ω/km.
INSULATION RESISTANCE:< 200MΩ x km.
OPERATING VOLTAGE:300/500V
CAPACITANCE (pF/m):120 pF/m
WORKING TEMPERATURE:-30-70°C
BENDING RADIUS:8x outer diameter
Areas of Usage: These multiple wire bare copper or tinned copper cables, produced with flame retardant durable PVC are used in the installation of motor vehicles.
PRODUCT CODE:FB1600
CROSS SECTION (Cu):16,00 mm²
STRANDED COPPER CONDUCTER
(Cu):126x0,39mm
INSULATION MATERIAL AND DIAMETER(mm ±0,05) :PVC (according to ISO 6722-1, CLASS B AND CLASS C) 6,80
MIN. WALL THICKNESS
(mm):0,52
APPROXIMATE WEIGHT
(kg/km):170,00
CONDUCTOR RESISTANCE:<1,16 Ω/km
WORKING TEMPERATURE:-40 to +105°C (CLASS B)
These multi-strand bare copper or tinned copper multi-core cables, produced in accordance with ISO 6722-1 CLASS B and CLASS C, are used in the installation of motor vehicles.
PRODUCT CODE:FRY4035
CORE NUMBERS x CROSS SECTION (mm²):4x0,35
STRANDED COPPER CONDUCTER
(N/mm):12x0,21
INSULATION MATERIAL AND DIAMETER(mm ±0,05):PVC (according to ISO 6722-1, CLASS B and CLASS C) 1,4
INSULATION THICKNESS
(mm):0,25
SHEATH THICKNESS
(mm):0,50
OVERALL DIAMETER:4,20
CONDUCTOR RESISTANCE:<54,4 Ω/km
WORKING TEMPERATURE:-40 to +105°C (CLASS B)